Usually there will be water overflow during this process, please prepare cleaning utensils such as a basin or towel:
a) Turn off the electroplating ball valve and pressure tank ball valve;
b) Open the gooseneck faucet to drain the residual water in the pipeline;
c) After the water no longer flows out, use the filter housing wrench to open the filter housing with the filter element;
d) Take out the old high-flow filter element and install a new filter element of the same specification;
e) Apply lubricant to the black "O" ring above the filter housing, and then put the "O" ring into the groove in the filter housing.
f) Tighten the filter housing in a vertical manner to avoid displacement of the "O" ring as much as possible.
g) Open the electroplating ball valve and the pressure barrel ball valve.